85
5.2 T
ANDEM
O
PERATION
ALS
20X
256
Settings in the functions menu -
syncronisation via Ethernet interface
Table [90] contains example addresses for a di-
rect connection (peer-to-peer) of the machines.
For connection to a network, the addresses
have to be provided by the network administra-
tor. It is recommended to connect both machines to the
same subnet which should have low network traffic.
[90] Required settings for master and slave for tandem synchroni-
sation via Ethernet interface.
Settings on:
Menu >Submenu
Function
Setting
Master and Slave
INTERFACE PARA
>EASYPLUGINTERPR
>
Interface
„TCP/IP SOCKET“
MACHINE SETUP >
Tandem synchron.
„UDP Tandem Port“
Master
MACHINE SETUP >
Tandem Operation
„Master“ or „FlipFlop master“
Tandem Distance
Set the distance [91A] between the dispensing edg-
es of the master and slave.
Slave IP address
127.000.000.001
INTERFACE PARA
>NETWORK PARAM. >
IP Addressassign
„Fixed IP address“
IP address
127.000.000.002
Slave
MACHINE SETUP >
Tandem Operation
„Slave“
INTERFACE PARA
>NETWORK PARAM. >
IP address
127.000.000.001
[91]] Distance (A) between the dispensing edges of the two
labellers
A
Summary of Contents for ALS 204
Page 1: ...ALS 204 206 256 SERVICE INSTALLATION MANUAL Labeller Edition 8 3 2012 Original version ...
Page 2: ......
Page 223: ......