Error: OD sensor is enabled. If the outer roll
diameter is less than the critical value, the signal
output „Error“ is activated. Additionally, the status
message „OD Material end“ appears.
OD Sens.polarity
function:
– Refers to the external OD light barrier (option).
– Sets the polarity of the OD sensor.
– Appears only if
MACHINE SETUP > Ext. OD sensor
= „Er-
ror“ or „Warning“
– Settings: [„Level low active“, „Level high activ“]
„Level low active“: Warning is displayed, if the
sensor signal is low.
„Level high activ“: Warning is displayed, if the
sensor signal is high.
4.1.5
INTERFACE PARA menu
Submenu >EASYPLUGINTERPR
Interface
function:
– Setting the active data interface
– Settings: [USB, Automatic, “TCP/IP Socket”,
“Serial Com1”
]
USB
:
USB 1.1 Interface.
USB IDs:
Automatic:
All interfaces can receive data, although
not simultaneously
.
“TCP/IP Socket”:
Data can be sent via a TCP/IP
socket to the Ethernet interface.
“Serial Com1
”:
Serial interface Com1.
CAUTION!
To avoid malfunctions:
Do not send data to more than one inter-
face at any one time.
During tandem operation, Com1 is used for
communication between master and slave ma-
chine. Therefore, the interface function may not
be set to „Automatic“ or to „Serial Com 1“.
Spooler mode
function:
– Settings: [“Single print job”, “Mult. print jobs”]
Dispenser ID no.
function:
– Labeller identification number
– Adjustment range: [0…31]
– Sets the identification number of the labeller. The la-
beller can then be called with the interface com-
mand: #!An (n=labeller ID). Setting up ID numbers
is particularly sensible for data transfer via
RS422/485 interface, if more than one labeller is
connected via a data link. Each of the labellers con-
nected then only processes the data addressed to it
using the “#!An” command
Spooler size
function:
– The size of the data buffer memory can be set to fit
customer requirements.
– Adjustment range: [96…256] KBytes; default: 96; in-
crement: 16
Offline mode
function:
– Settings: [
„Interf. disabled“
, „Interf. enabled“]
„Interf. disabled“: Easy-Plug commands are
not
accepted, while the machine is in offline mode.
„Interf. enabled“: Easy-Plug commands are
accepted in offline mode.
Interface delay
function:
– When switching from dispensing into adjustment
mode, the labeller interface is switched off. This pa-
rameter delays the switch-off of the interface by a
length of time that can be set.
– Adjustment range: [0…1000] ms; default: 0; incre-
ment: 100