170
8.1 T
YPES
OF
STATUS
MESSAGES
ALS
20X
256
5001
No gap found
– Material end, if no outer diameter
(OD) control is activated.
– The maximum limit for missing labels
was exceeded (
LABEL SETUP
>
Miss. la-
bel tol.
).
– The machine is not correctly set for
the type of label (
MACHINE SETUP
>
La-
bel sens. type
).
– Label length is not correctly set (
LA-
BEL SETUP
>
Label pitch
).
– Photoelectric label sensor is dirty.
– Photoelectric label sensor is incor-
rectly positioned.
– Photoelectric label sensor is not con-
nected correctly.
– Photoelectric label sensor is defec-
tive.
– Rotary encoder is not adjusted cor-
rectly.
Check the points listed above and
correct if necessary.
Press the
key to confirm the er-
ror message.
5002
Material end
– Material end (if the internal OD-con-
trol is activated).
Insert new label roll.
5009
Start error
– Refers to the standard start sensor
input (M12).
– The device received another start
signal while applying a label.
– Prerequisite:
MACHINE SETUP >
Start er-
ror stop
is set to “On”
.
Check the operation of the labeller;
increase distance between products
if required.
Set
MACHINE SETUP >
Start error stop
to
“off”.
5019
Startsig. overrun
– Too high start signal frequency
caused start signal buffer overflow.
– Possible causes: Distance between
product sensor and dispensing edge
is too high and/or to high product
Decrease distance between product
sensor and dispensing edge.
Decrease dispensing/conveyor
speed.
Increase product distance.
Status Status text
Cause
Action to take
[196] List of error messages
Summary of Contents for ALS 204
Page 1: ...ALS 204 206 256 SERVICE INSTALLATION MANUAL Labeller Edition 8 3 2012 Original version ...
Page 2: ......
Page 223: ......