52
3.2 C
ONNECTING
THE
SENSORS
ALS
20X
256
Function test
Prerequisite:
– Machine is in dispensing mode.
– OD sensor is activated (settings according to chap-
ter “Enabling” auf Seite 51).
If the light beam of the sensor [61B] meets the reflector
[61A], the following message appears after the next la-
bel has been dispensed:
Additionally, the following signals will be activated:
The message disappears immediately, if the light beam
stops falling on the reflector.
Note the following, when connecting to the
applicator
interface
:
– No status message will be displayed on the opera-
tion panel in case of low material (only the „OD sen-
sor“ signal will be activated)
– If no sensor is connected, the output signal
„OD sensor“ remains activated
ONLINE
OD sensor warn.
Interface
Signal name
Pin
Standard signal interface
Warning
8
Applicator interface
(optional)
OD-Sensor
16