61
4.1 F
UNCTION
MENU
4.1 F
UNCTION
MENU
ALS
20X
256
Standalone: This mode is used for loading firmware
(see chap. “Loading Firmware” on page 101) or
configurations (see chap. “Saving/loading a
configuration” on page 110) from CF card.
Language
function:
– Language of display text
– Settings: [German,
English
, French, Spanish, Dut-
ch, Danish, Italian, Polish, Turkish]
Access authoriz.
function:
– Limits access to functions from the menu. Changes
only come into force the next time the machine is
switched on.
– Settings: [User auto start, Supervisor, User, “Power-
up code”, “
Deactivated”
]
User auto start: Machine starts in user mode.
Supervisor:
Activates password check when the
machine changes from offline mode to the
parameter menu.
Valid keycodes:
Supervisor,
Production
.
User: Same as the “Supervisor” setting, except for
the valid keycodes.Valid keycodes: All
“Power-up code”:
Activates password check as
soon as machine is switched on. Once a valid
keycode has been entered, the machine switches to
Offline mode. The machine is then in either User,
Supervisor or Production mode, depending on
which keycode was entered.
“Deactivated”:
Password check deactivated
[75] Valid keycodes
[76] Effects of the different modes
CAUTION!
Improper use of the special functions only
accessible in production mode can damage
the labeller or stop it from functioning.
Settings in production mode should only
be adjusted by a trained servicing techni-
cian.
Default values
function:
– Settings: [Standard, “User defined”]
Standard:
Calling the "Factory settings" parameter
sets all parameters to the values defined by the
manufacturer.
“User defined”:
All current parameter settings are
adopted as default values. Calling the "Factory
settings" function then restores these values – even
after loading new firmware.
Factory settings
function:
– Settings: [Yes,
No
]
Yes: Restores all settings to factory settings
No: Has no effect
Store Parameters
function
– Saves the settings of the functions to a file on the
CompactFlash card (“FORMATS\” directory)
– Settings: [“
With adjust para
”, “Without adj. par”]
“With adjust para” Parameters that contain device-
specific settings are
included
in what is saved. The
names of the relevant parameters are marked with
a * in the text file.
Default file name:
„SETUPALL ALS xxx yy zzzzzzzzzzzzzzzz.FOR“.
Application
: Service
“Without adj. par”
:
Parameters that contain
device-specific settings are
excluded
from what
is saved.
Default file name:
„SETUP
ALS xxx yy zzzzzzzzzzzzzzzz
.FOR“.
Application
: Transferring settings to other
devices (when device-specific settings should
not be overwritten).
xxx = Machine type, e. g. 306
yy = RH or LH
zzzzzzzzzzzzzzzz = Serial number of the
CPU board
Mode
Keycode
User
-
-
-
Supervisor
-
-
-
-
-
Production
-
-
-
-
-
-
Mode
Effect
User
Access to the
LABEL SETUP
and
SERVICE DATA
menus
Supervisor
Access to all functions except produc-
tion functions (indicated in the over-
view)
Production
Access to all functions