The #!PC command
Syntax:
#!PC<Function ID>/<Value>
Immediate command for setting of function values. In
comparison to the #PC command, only the functions
listed afterwards can be set this way. The settings take
effect immediately.
[110] Functions which are setable with the #!PC function.
1)
Maxint = 4294967296
The #!SP command
Syntax:
#!SP
– In dispensing mode, the following is displayed after
sending the command:
– Continuing the dispensing: press the
button or
send #!SR.
<Function ID>
<Value>
Function
Function in menu
2005
n = 0 - Maxint
1)
Label counter
MACHINE SETUP > Dispense counter
2065
n = 0 - 16
Loads product profile no. „n“. A va-
lid product profile must be stored
under this number. After the com-
mand, a restart is executed.
LABEL SETUP
>
Load prod.profil
3213
n = 0 - 10000 ms
Signal delay after dispense end
SIGNAL INTERFACE >PLC SIGNALS>
Disp.end delay
6000
f = 0.0 - MAX m/min
Dispensing speed
LABEL SETUP > Dispense speed
6001
f = 0.0 - MAX m/min
Slew speed
LABEL SETUP > Slew speed
6002
f = 5.0 - 500.0 mm
Material length
LABEL SETUP > Label pitch
6003
f = 0.0 - 999.9 mm
Label stop position
LABEL SETUP > Lab. stop offset
6004
f = 15.0 - 9999.9 mm Start offset
LABEL SETUP > Start offset
6010
n = 0 - 100 %
Adjustment label sensor
MACHINE SETUP > Sensor Adjust
6016
n = 0 - Maxint
1)
Label amount
LABEL SETUP > Label stop quan.
6017
f = 0.0 - 1999.9 mm
Product length
LABEL SETUP > Product length