66
4.1 F
UNCTION
MENU
4.1 F
UNCTION
MENU
ALS
20X
256
Submenu >COM1 PORT
Baud rate
function:
– Data transfer rate
– Settings: [300, 600, 1200, 2400, 4800, 9600, 19200,
38400,
115200
] bit/s
No. of data bits
function:
– Settings: [7,
8
]
Parity
function:
– The parity bit is used to check the data transfer. If
the check reveals an error, a message is displayed
accordingly. The setting must be the same for both
transmitter and receiver. The normal set-up is for
transfer without a parity bit.
– Settings: [Odd, Even,
None
, “Always zero”]
Odd:
Odd parity. A parity bit is added in such a
way that the total number of 1 bits is odd.
Even:
Even parity. A parity bit is added in such a
way that the total number of 1 bits is even.
None:
No check bit.
“Always zero
”:
The check bit is always 0 (zero). For
transmission and reception without parity checking.
Stop bits
function:
– Settings: [
1
, 2]
Data synch.
function:
– Settings: [
RTS/CTS
, XON/XOFF, None]
RTS/CTS:
Data synchronisation by hardware
XON/XOFF:
Data synchronisation by software
None:
Handshake lines are not monitored
Frame error
function:
– Settings: [
Display
, Ignore]
Display: An error message is shown if frame errors
occur during serial transfer.
Ignore:
Frame errors are ignored, no error message
is displayed.
Submenu >NETWORK PARAM.
General rules for entering addresses:
– To change to the next/previous alphanumer-
ic character:
Press the
or
key.
– To confirm selection and move to the next
position:
Press the
key.
Alternatively, inputting can be carried out via
the WEB Server function.
– See “Web server” on page 95.
IP Addressassign
function:
– Settings: [“Fixed IP address”, DHCP]
“Fixed IP address”: This setting activates the “Net
mask” and “Gateway address” parameters (see
below).
DHCP:
The IP address is assigned automatically.
The IP address assigned is shown briefly in the
display while the system starts up.
IP address
function:
Enter IP Address in the form xxx.xxx.xxx.xxx
– Possible range for each xxx value: [0…255]
Net mask
function:
Enter address of the network mask in the form
xxx.xxx.xxx.xxx
– Possible range for each xxx value: [0…255]
– default: Depends on the IP address set (it is recom-
mended that you adopt the default value)
Gateway address
function:
Enter address of the gateway in the form
xxx.xxx.xxx.xxx
– Possible range for each xxx value: [0…255]
– 000.000.000.000 = no gateway address used
Port address
function:
– Adjustment range: [1024…65535]; default: 9100
Ethernet speed
function:
– Settings: [Automatic, “10M half duplex”, “10M full
duplex”, “100M half duplex”, “100M full duplex”]
Automatic:
The transfer rate is set automatically.
“10M Half duplex”:
Transfer rate = 10 MBit/s with
half duplex
operation.