149
7.5 S
IGNAL
I
NTERFACE
ALS
20X
256
LA-TO sensor
[159] Pattern of control signals over time for „LA-TO sensor“
applicators.
A
Duration is determined by label length and dispensing
speed. „Airstream Support“ switching to low means the label
is dispensed.
B
Duration t is determined by the backwards movement of the
applicator. The application cycle ends when the home
position signal is high again.
C
The output signal „Offline“ follows the input signal „Inhibit“.
D
The start signal is ignored because of the active „Inhibit“.
t
Start signal
Home position
Airstream support
Cylinder
(setable)
Offline
Cycle
Inhibit
Touch down
Additional signals with optional Applicator Interface:
B
C
A
D