178
9
R
EPAIR
9.1 T
ESTS
ALS
20X
256
9.1.1
Sensor test
Call the
SERVICE/DIAGNOS. > Sensor Test
function.
– Display:
alternating with:
– 00.01 = Identification number of the sensor
– 1 = value currently being transmitted by the sensor
“Labels”
Press the
key to change to the next sensor in
the list
Press the
key to change to the preceding sen-
sor in the list
Sensor Test
00.01 1
Sensor Test
Labels. 1
Sensor ID
Name
Value
Test
00.01
Labels.
(Label sensor)
1 or 0
Move label material through the sensor; a gap
between labels (punch) must cause a change
between 1 and 0. If no change takes place:
Adjust the sensor (
MACHINE SETUP > Sensor
Adjust
)
00.02
Starts.
(Photoelectric product sen-
sor)
1 or 0
Breaking the light beam must cause a change
between 1 and 0.
00.03
Capaci.
(capacitive label sensor)
1 or 0
Move label material through the sensor; a gap
between labels (punch) must cause a change
between 1 and 0.
00.04
Diamet.
(external photoelectric RD
sensor)
1 or 0
Breaking the light beam must cause a change
between 1 and 0.
00.05
APSF f.
(rotary encoder frequency)
xxx Hz
Shows current rotary encoder frequency when
labeller operating with automatic speed adjust-
ment.
Increase/decrease belt speed
– Displayed frequency must increase/de-
crease accordingly
00.06
APSF s.
(rotary encoder speed)
xx.xx m/min
Shows current belt speed when labeller oper-
ating with automatic speed adjustment.
Increase/decrease belt speed
– Displayed speed must increase/decrease
accordingly
00.07
APSF p.
(rotary encoder - pulses)
xxxx
– Counter for rotary encoder pulses
– max. count: 32767
– When exceeded rolls over to 0
[197] Overview for the “MACHINE SETUP > Sensor Test“
9
R
EPAIR
9.1
TESTS
Summary of Contents for ALS 204
Page 1: ...ALS 204 206 256 SERVICE INSTALLATION MANUAL Labeller Edition 8 3 2012 Original version ...