AUX DC Inverter Free Match 50HZ R410A
Free Match outdoor unit
50
1. Function Introduction
Anti-cold-air (Heat pump only)
When starting the heating operation, the fan speed is regulated automatically from the lowest grade to the preset
level, according to the temperature rising of evaporator. The function can prevent cold air blowing out at the
beginning of the operation, which avoids the discomfort to the user.
Self-diagnosis function
Monitoring some abnormal operations or parts failures, which happens microcomputer of the air
conditionerwhichswitch off and protect the system automatically. Meanwhile, the error or protection code will be
displayed on the indoor unit.
24-hour timer
User can set on the timer to turn on or off the air conditioner any time within 24 hours.
Force cooling
This function is convenient when user can’t find the remote controller.
Intelligent defrosting
Normal defrost function can only be operated in certain time, but AUX commercial air conditioner’s intelligent defrost
can start automatically according to the surrounding condition.
Auto restart
If the machine is suddenly shut down during operation, the unit will record the operating mode, and restore to it when
the power is on.
Sleep Mode
User can select mode after pressing time-off button, this function will adjust temperature automatically, which makes
a comfortable sleep environment and save energy.
Low ambient cooling
The air conditioner with a special built-in low ambient cooling component can be used in temperature as low as -15C
for cooling operation.
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...