background image

E§§HNIKA

INSTALLATION MANUAL
MANUAL DE INSTALACIÓN
MANUEL D’INSTALLATION
MANUALE D’INSTALLZIONE
MANUAL DE INSTALAÇÃO
INSTALLATIONS-HANDBUCH

E°XEIPI¢IO E°KATA™TA™H™

àçëíêìäñàü èé ìëíÄçéÇäÖ

System Air Conditioner

Aire acondicionado sistemático 

Climatiseur numérique multifonctionnel 

Sistema Aria Condizionata 

Sistema Ar Condicionado 

Klimaanlage System 

™‡ÛÙËÌ· ∫ÏÈÌ·ÙÈÛÌÔ‡ 

ëËÒÚÂÏÌ˚È ÇÓÁ‰Û¯Ì˚È äÓ̉ˈËÓÌÂ 

E S F I P D G R DB98-05180A(2)

AVMWH020CA0
AVMWH032CA0
AVMWH040CA0
AVMWH052CA0
AVMWH072CA0
AVMWH020EA(B)0
AVMWH026EA(B)0
AVMWH035EA(B)0
AVMWH052EA(B)0
AVMWH070EA(B)0

Heat pump

AVMWC020CA0
AVMWC032CA0
AVMWC040CA0
AVMWC052CA0
AVMWC072CA0
AVMWC020EA(B)0
AVMWC026EA(B)0
AVMWC035EA(B)0
AVMWC052EA(B)0
AVMWC070EA(B)0

Cooling only

ENGLISH

ESP

A

Ñ

OL

FRAN

Ç

AIS

IT

ALIANO

POR

TUGU

Ê

S

DEUTSCH

RUSSIAN

Summary of Contents for AVMWH020CA0

Page 1: ...Sistema Aria Condizionata Sistema Ar Condicionado Klimaanlage System E S F I P D G R DB98 05180A 2 AVMWH020CA0 AVMWH032CA0 AVMWH040CA0 AVMWH052CA0 AVMWH072CA0 AVMWH020EA B 0 AVMWH026EA B 0 AVMWH035EA...

Page 2: ...lve Kit Installation 9 Connecting the Refrigerant Pipe 12 Cutting Flaring the Pipes 13 Performing Leak Test Insulation 14 Drain Hose Installation 15 Connecting the Connection Cord 16 Assigning Address...

Page 3: ...rforming Leak Test Insulation 14 Drain Hose Installation 15 Connecting the Connection Cord 16 Assigning Address to Indoor Unit 17 Additional Functions 18 Bio pure Filter Installation optional 19 Troub...

Page 4: ...ine oil Sulphide gas Special environmental conditions If you must install the unit in such conditions first consult your dealer E 4 Accessories The following accessories are supplied with the indoor u...

Page 5: ...n support its weight Maintain sufficient clearance around the indoor unit Make sure that the water dripping from the drain hose runs away correctly and safely The indoor unit must be installed in this...

Page 6: ...E 6 Deciding on Where to Install the Indoor Unit cont Drawing of the indoor unit 020 026 032 035 040 Unit mm Air In Front view Rear view Air out...

Page 7: ...E 7 ENGLISH 052 070 072 Drawing of the indoor unit Front view Rear view Unit mm...

Page 8: ...ards 2 If you are fixing the indoor unit to a Then follow Steps Wall 3 Window frame 4 to 6 3 Fix the installation plate to the wall in a manner appropriate to the weight of the indoor unit If you are...

Page 9: ...refrigerant pipe to each indoor unit A B and C The liquid and gas pipes should not be crossed when piping connection 4 Insulate the connection piping A joint part of pipe needs double thickness of in...

Page 10: ...ble to another electronic expansion valve kit Room A Room B Outdoor unit Another distributor kit Room C 2 Connect the AC power cable and communication cable to each indoor unit A B and C 3 Align the S...

Page 11: ...icates 0 1 and 2 that means the SW51 is set to 0 the SW52 is set to 1 and the SW53 is set to 2 If the communication error occurs in distributor the Er C0 message will be shown on the display alternati...

Page 12: ...stalled area is warm and humid There are two refrigerant pipes of different diameters A smaller one for the liquid refrigerant A larger one for the gas refrigerant A short length of piping is already...

Page 13: ...incorrectly 2 To prevent any gas from leaking out remove all burrs at the cut edge of the pipe using a reamer 3 Slide a flare nut on to the pipe and modify the flare 4 Check that the flaring is correc...

Page 14: ...r thicker Acrylonitrile Butadien Rubber separately around each refrigerant pipe 1 Wind insulating tape around the pipes 2 Finish wrapping insulating tape around the rest of the pipes leading to the ou...

Page 15: ...downwards as shown in the illustrations above Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside When passing the...

Page 16: ...te the connection cord through the side of the indoor unit and connect the cable to terminals refer to the figure below 2 Route the other end of the cable to the outdoor unit through the ceiling the h...

Page 17: ...oller 4 If you install optional accessories such as the wired remote controller centralized controller etc see an appropriate installation manual 5 If an optional accessory is not installed you do not...

Page 18: ...K6 K7 K8 SW04 K5 2 C compensation 5 C compensation Switch No Switch ON Switch OFF Control of electronic expansion valve at the indoor unit off When an indoor unit off makes refrigerant noise set K11...

Page 19: ...Deodorizing filter Deodorizing filter 1 Bio pure filter 1 Accessories Insert the filter in the filter holder and press the three tabs until you hear a click 2 1 Open the front grille by pulling on the...

Page 20: ...tor Below 450RPM for 15 minutes Error of outdoor temperature sensor Error of COND sensor Error of DISCHARGE sensor 1 No communication for 2 minutes between indoor unit and outdoor unit communica tion...

Page 21: ...close 2 Error of electronic expansion valve open 3 Breakaway of EVA OUT sensor 4 Breakaway of EVA IN sensor 5 Breakaway of COND MID sensor 6 2nd detection of refrigerant completely leak 7 2nd detectio...

Page 22: ...n indoor unit OPEN SHORT error of eva in sensor in indoor unit OPEN SHORT error of eva out sensor in indoor unit EEPROM error EEPROM option error Error of fan starting Error of outdoor unit Communicat...

Page 23: ...Parts List 24 O O O OP P P PT T T TI I I IO O O ON N N NA A A AL L L L A A A AC C C CC C C CE E E ES S S SS S S SO O O OR R R RI I I IE E E ES S S S Chapter E 23 ENGLISH...

Page 24: ...cable 1 Transmitter communicationcable 1 Transmitter Accessories Owner s instructions 1 Installation manual 1 Function controller 1 Cable tie 2 Cable clamp 6 M4x16 tapped screw 7 Function Controller...

Page 25: ...Memo E 25 ENGLISH...

Page 26: ...ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO FABRICADO POR DIESE KLIMAANLAGE IST FABRIZIERT V...