AUX DC Inverter Free Match 50HZ R410A
Free Match outdoor unit
60
6. Installation
6.1 Spacing Reserved Between the Surrounding of Indoor Unit and Barrier
6.2 Hoisting of Indoor Unit
◇
The wall for installing indoor unit should be firm to prevent vibration. Horizontally install hanging plate on the wall with
four cruciform screws to keep laterally horizontal and longitudinally vertical.
◇
Drill a Φ70 Auxiliary pipeline hole on lower left side or lower right side of hanging plate. The position of hole should slightly
incline downwards.
◇
Hang indoor unit on hanging plate and move the unit to left or right to ensure hanging hook is correctly positioned on the
hanging plate.
6.3 Installation of Sterilization Net
◇
Uplift panel of indoor unit, pull out the bulge in the middle of air filter downwards after uplifting;
◇
Completely snap sterilization net inside accessory bag into sterilization mounting support on air filter;
◇
Put back air filter in the original way, close the panel of indoor unit and tightly clamp;
◇
Push the lower left side and lower right side of indoor unit towards hanging plate until hanging hook inserts into groove
and sends click sound.
6.4 Drainage Checking
In case of maintenance, remove grille from casing of the unit according to the following procedures:
◇
As shown in right diagram, remove two screw caps on both sides of the front grille and then screw down two fixing screws.
◇
Pull the lower end of grille cover towards oneself to remove it.
>
5cm
>
5cm
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...