AUX DC Inverter Free Match 50HZ R410A
Free Match outdoor unit
70
2. Specification
DC
INVERTER
Model
AM2-H18/4DR1A
AM3-H24/4DR1A
AM3-H27/4DR1A
System Format
1 drive 2
1 drive 3
1 drive 3
Capacity
Cooling
Btu/h
17060(7530-19790)
24050(6824~25760)
25660(7524~27600)
kW
5.0(2.2-5.8)
7.05(2.0~7.55)
7.52(2.2~8.1)
Heating
Btu/h
18766(9385-21770)
26440(8138~28150)
27125(8138~29900)
kW
5.5(2.75-6.38)
7.75(2.2~8.25)
7.95(2.39~8.75)
Electric Data
Power Supply
V~,Hz,
Ph
220~240,50,1
220~240,50,1
220~240,50,1
Cooling Power
Input
W
1540(280-2100)
2280(550-3100)
2350(580-3200)
Heating Power
Input
W
1530(280-2100)
2380(510-2750)
2480(560-2830)
Rated Current
(cooling&heati
ng)
A
6.6/6.5
10.5/10.9
11.0/11.5
Performance
SEER/SCOP
W/W
6.20/4.03
6.15/4.08
6.14/4.10
Energy Rate
A++/A+
A++/A+
A++/A+
DC
Inv.Compressor
Model
DA150S1C-20KZ
DA250S2C-30MT
DA250S2C-30MT
Quantity
1
1
1
Type
Twin Rotary
Twin Rotary
Twin Rotary
Brand
GMCC
GMCC
GMCC
Capacity
W
4590
7690
7690
Input
W
1205
2120
2120
Power Supply
V~,Hz,
Ph
220~240,50,1
220~240,50,1
220~240,50,1
Rated Current
A
8.35
8.85
8.85
Operating
Frequency
Hz
60
60
60
Frequency
Range
12~120 S
-1
12~120 S
-1
12~120 S
-1
Refrigerant Oil ml
500(VG74)
820(VG74)
820(VG74)
Outdoor DC
Inverter Fan
Motor
Model
CW70B-ZL
CW70B-ZL
CW70B-ZL
Type
DC Inverter
DC Inverter
DC Inverter
Brand
Panasonic
Panasonic
Panasonic
Quantities
1
1
1
Insulation
Class
B
B
B
Safe Class
IP44
IP44
IP44
Input Power
W
90
90
90
Output Power
W
70
70
70
Capacitor
uF
/
/
/
Speed
r/min
900-200
900-200
900-200
Outdoor Fan
Material
Plastic
Plastic
Plastic
Diameter
mm
Ф470×140
Ф470×140
Ф470×140
Fan Quantity
1
1
1
Outdoor Coil
a.Number Of
Row
1.5
2.5
2.5
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...