AUX DC Inverter Free Match 50HZ R410A
Installation
92
Note:
This chart is for explanation purposes. An actual installation will differ from this according to the site conditions.When
making an oil loop the radius of the bend should be between 1.5 and 2 times the pipe diameter.
8.3Electrical connection
8.3.1Electrical connection precaution
Warning
Installation of electric items must be carried out by qualified, professional technicians.
An isolated circuitry should be fixed with whole-pole disconnection devices, which is with at
least 3mm gap of touch point . Power supply and indoor to outdoor connection wire should use
special cable.
Providing the necessity of installation or replacement, the professional technician of service
store appointed by manufacturer must be required, while self-operation by users is prohibited.
In case of any electric shock accident, the creepage protection devices /power supply on-off
switch and breaker must be required with.
The specification of fuse for single phase control board is F5AL 250V, while for 3 phase control
board, both indoor and outdoor unit, it is F3.15AL 250V
。
Machine must be earthed surely. or
it’ll be probably causecreepage.
Notice
The earth line is neither allowed to connect to gas pipe, water pipe ,circuitry of telephone or
lighting rod, nor to the earth line of other devices.
Others
Please fix power supply cord and connection wires of indoor and outdoor, in accordance with
circuit diagram
Fix the cords into terminal boards properly and safely with cable fixation tools to avoid any
danger caused by the power cord under outside forces.
After fixation, use bind tape (affixed) to bind wires avoiding any collision with other components
like compressor, copper pipes…etc
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...