AUX DC Inverter Free Match 50HZ R410A
Installation
93
8.3.2 Electrical connection
Wiring diagram of indoor & outdoor, refer to the section of part 1
Recommendation of power supply cord
Power supply:220~240V,50Hz
Capacity (BTU)
Model
Power
supply
Indoor power cable
7000
AMWM-H07/4R1(#)
AMSD-H07/4R1
Outdoor unit
220-240V
~
50Hz
IndoorUnit
220-240V
~
50Hz
3×1mm2
9000
AMWM-H09/4R1(#)
AMCA-H09/4R1A
AMCF-H09/4R1
AMSD-H09/4R1
3×1mm2
12000
AMWM-H12/4R1(#)
AMCA-H12/4R1A
AMCF-H12/4R1
AMSD-H12/4R1
3×1mm2
18000
AMWM-H18/4R1(#)
AMCA-H18/4R1A
AMCF-H18/4R1
AMSD-H18/4R1
3×1mm2
Power
supply
Series
Max. Current(Normal)
Rated cooling
(35/24 27/19)
Maximum
frequency operation
(39/26 32/23)
Maximum capacity
operation
(43/26 32/23)
Outdoor unit
220-240V~50Hz
1 drive 2(18K)
10.9
11.6
9.50
1 drive 3(24K)
15.4
16.9
14.8
1 drive 3(27K)
15.6
17.1
15.0
1 drive 4(36K)
22.4
24.1
21.9
1 drive 5(42K)
23.0
24.7
22.6
Outdoor unit
187V~50Hz
1 drive 2(18K)
11.7
12.1
11.8
1 drive 3(24K)
16.6
17.3
16.1
1 drive 3(27K)
16.8
17.5
16.3
1 drive 4(36K)
22.6
24.3
22.1
1 drive 5(42K)
23.2
24.9
22.8
Notice:
◇
Above mentioned power supply cord is the cable which connect air on-off of indoor to indoor/outdoor unit. Power
supply cord of indoor/outdoor unit is the power supply cable connecting indoor and outdoor unit
◇
The section area of power supply cord core is minimized one. To avoid voltage pressure dropped down, while
longer power supply cord needed, the section area should be enlarged for one gauge.
◇
The connection wires to indoor unit is the cable of 27IEC53(RVV) type, 300/500V; while the connection wires to
outdoor unit and the connection wires from outdoor to indoor unit is the multi-end of cable (neoprene)of
245IEC57(YZW)type,300/500V. if the single core with double skin type of cable is chosen for installation,, please
choose 1# gauge of section area and wrapped with special jacket for electrician.
◇
All of the ceiling/floor type unit is without accessorial electric heating
8.3.3 Wire connection
Indoor wire connection
Remove electric control box cover of indoor unit, connect the wires in accordance with the electridiagram
mentioned on the back of the cover. The wire ends must be tightly fixed into terminal boards. The earth wire must be
fixed into appointed position.
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...