AUX DC Inverter Free Match 50HZ R410A
Free Match outdoor unit
52
2. Specfication
Model
Indoor
Unit
AMWM-H07/4R1(L)
AMWM-H09/4R1(L)
AMWM-H12/4R1(L)
AMWM-H18/4R1(L)
Capacity
Cooling
Btu/h
7165(3855-9220)
8870(4780-11260)
12285(5800-12625)
17745(8530-19790)
kW
2.05(1.13-2.70)
2.55(1.40-3.30)
3.60(1.70-3.70)
5.20(2.50-5.80)
Heating
Btu/h
7510(3340-8530)
9215(4095-10240)
12625(5120-12625)
18085(7680-19790)
kW
2.15(0.98-2.50)
2.65(1.20-3.00)
3.70(1.50-3.70)
5.0(2.25-5.80)
Electric Data
Power Supply
V~,Hz
,Ph
220
~
240,50,1
220
~
240,50,1
220
~
240,50,1
220
~
240,50,1
Cooling Power
W
40(12
~
68)
40(12
~
68)
40(12
~
68)
63(16
~
88)
Heating Power
W
40(12
~
68)
40(12
~
68)
40(12
~
68)
63(16
~
88)
Indoor
Fan Motor
Model
/
YYK19-4
YYK19-4
YYK19-4
YYK30-4
Output Power
W
19
19
19
30
Capacitor uF
1.5
1.5
1.5
3
Speed
(Hi/Mi/Lo)
r/min
1030/900/850
1030/900/850
1030/900/850
1230/1080/970
Indoor Coil
Number Of Row
/
2
2
2
2
Tube x Row
Pitch
mm
20.5x 12.7
20.5x 12.7
20.5x 12.7
20.5x 12.7
Fin Pitch
mm
1.4
1.4
1.4
1.4
Fin Material
/
Hydrophilic aluminum fin
Tube Material mm
φ7
,
Inner grooved
Coil L x H x W
mm
602x164x 25.4
602x164x 25.4
602x164x 25.4
722x164x 25.4
Heat Exchange
Area
m
2
5.58
5.58
5.58
5.58
Performance
Air Flow Volume
CFM
969/765/672
969/765/672
969/765/672
1700/1462/1170
m
3
/h
570/450/395
570/450/395
570/450/395
1000/860/688
Sound Pressure
dB(A)
40/38/34
40/38/34
42/40/36
45/42/35
Dimension
Net Dim
(W*D*H)
mm
800×300×198
800×300×198
800×300×198
970×315×235
Pack Dim
(W*D*H)
mm
835×355×255
835×355×255
835×355×255
1010×370×290
Weight
Net
kg
10
10
10
13
Gross
kg
11.5
11.5
11.5
16
Refrigerant Type
/
R410a
R410a
R410a
R410a
Pipe Dia
Liquid Side
mm(in
ch)
6.35(1/4)
6.35(1/4)
6.35(1/4)
6.35(1/4)
Gas Side
mm(in
ch)
9.52(3/8)
9.52(3/8)
9.52(3/8)
12.7(1/2)
Drainage
mm
16.5
16.5
16.5
16.5
Loading Qty
20/40/40H
unit
422/830/948
422/830/948
422/830/948
286/588/675
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...