AUX DC Inverter Free Match 50HZ R410ALow ESP Ducted type
37
2. Specfication
Model
Indoor
Unit
AMSD-H07/4R1
AMSD-H09/4R1
AMSD-H12/4R1
AMSD-H18/4R1
Capacity
Cooling
Btu/h
7506(3855-9220)
8872(5120-12115) 12280(5835-13135) 17400(8530-19790)
kW
2.20(1.13-2.70)
2.60(1.50-3.55)
3.60(1.71-3.85)
5.10(2.50-5.80)
Heating
Btu/h
8530(4575-10820)
9895(5800-12450) 13650(6480-13375) 19790(9690-21835)
kW
2.50(1.34-3.17)
2.9(1.70-3.65)
4.00(1.90-3.92)
5.8(2.84-6.40)
Electric
Data
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
220~240,50,1
220~240,50,1
Cooling Power Input
W
45
45
75
137
Heating Power Input W
45
45
75
137
Fan Motor
Model
/
FP20A
FP20A
FP25A
FP40A
Output Power
W
20
20
25
40
Capacitor
uF
1.5
1.5
2
3
Speed (Hi/Mi/Lo)
r/min
1060/790/610/510
1060/790/610/510
1060/890/800/700
1160/1070/940/800
Indoor Coil
Number Of Row
/
2
2
2
2
Tube x Row Pitch
mm
20.5x 12.7
20.5x 12.7
20.5x 12.7
20.5x 12.7
Fin Pitch
mm
1.4
1.4
1.4
1.4
Fin Material
/
Hydrophilic
aluminum
Hydrophilic
aluminum
Hydrophilic aluminum
Hydrophilic aluminum
Tube Dia.& Material mm
φ7
,
Inner
grooved
φ7
,
Inner
grooved
φ7
,
Inner grooved
φ7
,
Inner grooved
Coil L x H x W
mm
640x205x 25.4
640x205x 25.4
640x205x 25.4
960x205x 25.4
Heat Exchange
Area
m
2
4.24
4.24
4.24
6.36
Air Volume
m
3
/h
420/336/294
420/336/294
580/464/406
860/688/602
Sound Pressure Noise Level
dB(A)
30/26/23
30/26/23
32/28/25
38/35/32
Dimension
Net Dim (W*D*H)
mm
840×460×185
840×460×185
840×460×185
1160×460×185
Packing
Dim(W*D*H)
mm
1030×545×250
1030×545×250
1030×545×250
1350×545×250
Weight
Net
kg
16.5
16.5
17.5
21
Gross
kg
20
20
21
26
Refrigerant Type
/
R410a
R410a
R410a
R410a
Pipe Dia
Liquid Side
mm(inch)
6.35(1/4)
6.35(1/4)
6.35(1/4)
6.35(1/4)
Gas Side
mm(inch)
9.52(3/8)
9.52(3/8)
12.7(1/2)
12.7(1/2)
Drainage
mm
16.5
16.5
16.5
16.5
Loading
Qty
20/40/40H
unit
198/396/440
198/396/440
198/396/440
144/297/330
Note:
1. Cooling capacity test Condition:(27
℃
DB,19
℃
WB Indoor/35
℃
DB,24
℃
WB Outdoor);
Heating capacity test Condition:(20
℃
DB Indoor/7
℃
DB,6
℃
WB Outdoor);
connecting pipe length: 5M.
2. Datas may be changed withunit improvement. We keep the right to change the datas or specifications
withoutprior notice, please follow the datas listed on the nameplate.
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...