7. Explode view
AMCF-H09/4R1,AMCF-H12/4R1,AMCF-H18/4R1
No.
Material Code
Part Name
Qty
Remark
1
16420012000002
Air-inlet filter
2
2
16420010000002
Air-inlet grill(white)
2
3
16420015000002
Left side adornment plank
1
4
16421038000207
The electricity controls a box
1
5
16421038000208
The electricity controls a box of cover
1
6
11220544000008
Compress tightly electric wire seat
1
7
16427001000064
Terminal board
1
8
16422005000033
Transformer
1
9
11330010000088
Capacitor
1
10
11222542000029
PCB board
1
11
16430001000196
Motor
1
YSK-40W-4
12
16420014000007
The left side covers
1
13
16421001000029
Left suspend plate
1
14
16321006000005
Bracket board welding assembly of left-hand
1
15
16428001000034
Left foam
1
16
16421018000004
Chassis welding assembly
1
17
16324006000014
Evaporator assembly
1
17.1
16325006000018
Evaporator tube kit
1
17.2
16325006000017
Evaporator outlet assembly
1
17.3
16325006000016
Evaporator inlet pipe assembly
1
Summary of Contents for AMCA-H09/4R1A
Page 1: ...AUX DC Inverter Free Match 50HZ R410A 1 SERVICE MANUAL DC Inverter Free Match R410a ...
Page 80: ...AUX DC Inverter Free Match 50HZ R410A Free Match outdoor unit 80 ...
Page 107: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 107 Outdoor protection phase sequence ...
Page 108: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 108 Cooling high pressure protection ...
Page 109: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 109 Heating high pressure protection ...
Page 110: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 110 Cooling low pressure protection ...
Page 111: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 111 Heating low pressure protection ...
Page 115: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 115 Sensor failure protection ...
Page 117: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 117 Poor effect ...
Page 118: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 118 ...
Page 119: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 119 Abnormal sound or viberation ...
Page 120: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 120 ...
Page 121: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 121 Abnormal odor ...
Page 123: ...AUX DC Inverter Free Match 50HZ R410A Trouble shooting 123 Air conditioner water leakage ...
Page 132: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 132 Wired controller XK 05 ...
Page 133: ...AUX DC Inverter 1 Drive1 50HZ R410A Sensorresistance table 133 ...