background image

Instructions manual

UV-c air disinfection system             

Model Scarecrow 15

Summary of Contents for Scarecrow 15

Page 1: ...Instructions manual UV c air disinfection system Model Scarecrow 15 ...

Page 2: ...hnical specifications 2 Product operation 3 Machine components 3 1 Tactile button 3 2 Active carbon filter and hepa filter 3 3 Air circulation 3 4 UV c lamps 4 Maintenance 5 Product applications 6 Safety recommendations indications and warnings 3 3 3 4 5 6 6 6 7 7 8 10 10 ...

Page 3: ...disinfection and suitable for various types of viruses including SARS CoV The point of maximum germicidal efficiency when the DNA and RNA chains absorb a greater amount of radiation corresponds to wavelengths of 260 nm which coincides with the wavelength of UV C light SCARECROW disinfection system generates constant forced ventilation in which the air in a room is recirculated disinfecting it insi...

Page 4: ...l aluminum structure Standard programs 10 working speeds Low energy consumption Operation light sign and tactile button for program selection Active carbon filter and HEPA 13 filter for a first mechanical filtration UVC lamps ensure continuous circulating air disinfection Work areas calculated with a height of 3 m Completely safe device can be used in the presence of people With wheels for movemen...

Page 5: ...ctile button is pressed for the first time speed mode 1 will start and the button will be illuminated with a blinking blue light Pressing again speed mode 2 will be selected and the light flashing will be faster With each press the next speed mode will be selected and the flashing will be faster until it reaches speed mode 10 in which the maximum speed is achieved and the button will be illuminate...

Page 6: ...rer to replace the affected lamp 3 MACHINE COMPONENTS 3 1 Tactile button By means of a tactile button it is possible to start and stop the operation of the device as well as to change the operating speeds 3 2 Active carbon filter and hepa filter The Scarecrow does a first mechanical particle filtration and odor removal For this it has an active carbon filter and a HEPA H13 filter With this first f...

Page 7: ... maximum speed is 60dB 10 working speeds are available 3 4 Lámparas UV c These lamps emit UV C radiation with a wavelength of 254 nm which is why they have a germicidal capacity for viruses bacteria and other microorganisms Being inside the machine the use of the device is safe with people inside the disinfected room As they do not have wavelengths less than 250 nm the lamps do not produce ozone P...

Page 8: ...of deterioration Unplug the device when not in use or when cleaning Any damaged part should only be replaced by the manufacturer If the device is disassembled or shows manipulation signs without the consent of the manufacturer the product warranty will be lost Lamps must be replaced after 9000 hours of use they will present a 25 emission drop In order to maintain the efficiency of the system it is...

Page 9: ... HEPA 13 filter must be replaced after 12 months of use The filter can be changed by non specialized personnel Consult the manufacturer for a replacement Warning Make sure that the machine is electrically disconnected before replacing any filter The HEPA 13 filter must always be mounted in the innermost part 12 12 ...

Page 10: ...linics laboratories residences schools shops restaurants coffee shops hotels spas beauty centers hairdressers gyms and sports centers 6 Safety recommendations indications and warnings This device works with lamps that generate UV C radiation This radiation produces harmful effects on the skin and eyes It can cause skin erythema conjunctivitis and or photokeratitis cornea s inflammation UV ...

Page 11: ... and the skin must be covered with laboratory coats and nitrile gloves In case of exposure to UVC radiation it is recommended to consult an ophthalmologist if eye damage is suspected and to treat skin lesions immediately Always use this device connected to a protected electrical line with a differential of at least 30 mA When moving the device it is recommended to apply force to the lower half of ...

Page 12: ......