Version 5.6
93
November 2008
SIP User's Manual
3. Web-Based Management
ini File Field Name
Web Parameter Name
Valid Range and Description
not identified as channel-id #16, but is still carried into the
timeslot #16.
When this bit is set, the channel ID #16 is considered as a valid
B-channel ID, but timeslot values are converted to reflect the
range 1 to 15 and 17 to 31. This is the new QSIG mode of
operation. When this bit is not set (default), the channel_id #16 is
not allowed, as for all ETSI-like standards.
[64]
USE T1 PRI = PRI interface type is forced to T1.
[128]
USE E1 PRI = PRI interface type is forced to E1.
[256]
START WITH B CHAN OOS = B-channels start in the Out-
Of-Service state (OOS).
[512]
CHAN ALLOC LOWEST = CC allocates B-channels
starting from the lowest available B-channel id.
[1024]
CHAN ALLOC HIGHEST = CC allocates B-channels
starting from the highest available B-channel id.
Note:
When using the
ini
file to configure the device to support
several ISDNGeneralCCBehavior features, add the individual feature
values. For example, to support both [16] and [32] features, set
ISDNGeneralCCBehavior = 48 (i.e., 16 + 32).
CAS Configuration (These parameters only appear if the protocol Type is
CAS Table
[CASTableIndex_x]
Defines CAS protocol for each trunk ID from a list of CAS protocols
defined by the parameter CASFileName_Y.
For example:
CASFileName_0 = 'E_M_WinkTable.dat'
CASFileName_1 = 'E_M_ImmediateTable.dat'
CASTableIndex_0 = 0
CASTableIndex_1 = 0
CASTableIndex_2 = 1
CASTableIndex_3 = 1
Trunks 0 and 1 use the E&M Winkstart CAS protocol, while trunks 2
and 3 use the E&M Immediate Start CAS protocol.
Note:
For additional CAS table
ini
file parameters (CASFileName_0,
CASFileName_1, CASFileName_7, and CASTablesNum), refer to
''E1/T1 Configuration Parameters'' on page
.
Dial Plan
[CasTrunkDialPlanName]
The Dial Plan name that is used on a specific trunk.
The range is up to 11 character strings.
Miscellaneous
PSTN Alert Timeout
[TrunkPSTNAlertTimeout_I
D]
Alert Timeout (ISDN T301 timer) in seconds for outgoing calls to
PSTN. This timer is used between the time that a SETUP message
is sent to the Tel side (IP-to-Tel call establishment) and a CONNECT
message is received. If ALERT is received, the timer is restarted.
In the
ini
file parameter,
ID
depicts the trunk number, where 0 is the
first trunk.
The range is 1 to 600. The default is 180.
Digital Out-Of-Service
Behavior
[DigitalOOSBehaviorFor
Trunk_ID]
Determines the method for setting digital trunks to Out-Of-Service
state per trunk.
[-1]
Not Configured = Use the settings of the DigitalOOSBehavio
parameter for per device (default).
Summary of Contents for Mediant 2000
Page 1: ...Document LTRT 68808 November 2008 User s Manual Version 5 6 ...
Page 2: ......
Page 18: ...SIP User s Manual 18 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 254: ...SIP User s Manual 254 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 334: ...SIP User s Manual 334 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 342: ...SIP User s Manual 342 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 408: ...SIP User s Manual 408 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 414: ...SIP User s Manual 414 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 418: ...User s Manual Version 5 6 www audiocodes com ...