SIP User's Manual
336
Document #: LTRT-68808
Mediant
2000
The Call Progress Tones section of the
ini
file comprises the following segments:
[NUMBER OF CALL PROGRESS TONES]:
Contains the following key:
'Number of Call Progress Tones' defining the number of Call Progress Tones that are
defined in the file.
[CALL PROGRESS TONE #X]:
containing the Xth tone definition (starting from 1 and
not exceeding the number of Call Progress Tones defined in the first section) using the
following keys:
•
Tone Type:
Call Progress Tone types:
♦
[1]
Dial Tone
♦
[2]
Ringback Tone
♦
[3]
Busy Tone
♦
[7]
Reorder Tone
♦
[8]
Confirmation Tone (Applicable only to Analog devices)
♦
[9]
Call Waiting Tone (Applicable only to Analog devices)
♦
[15]
Stutter Dial Tone (Applicable only to Analog devices)
♦
[16]
Off Hook Warning Tone (Applicable only to Analog devices)
♦
[17]
Call Waiting Ringback Tone
♦
[23]
Hold Tone
•
Tone Modulation Type:
Either Amplitude Modulated (1) or regular (0).
•
Tone Form:
The tone's format can be one of the following:
♦
Continuous (1)
♦
Cadence (2)
♦
Burst (3)
•
Low Freq [Hz]:
frequency (in Hz) of the lower tone component in case of dual
frequency tone, or the frequency of the tone in case of single tone. This is not
relevant to Amplitude Modulated (AM) tones.
•
High Freq [Hz:
frequency (in Hz) of the higher tone component in case of dual
frequency tone, or zero (0) in case of single tone (not relevant to AM tones).
•
Low Freq Level [-dBm]:
generation level 0 dBm to -31 dBm in dBm (not relevant
to AM tones).
•
High Freq Level:
generation level. 0 to -31 dBm. The value should be set to 32 in
the case of a single tone (not relevant to AM tones).
•
First Signal On Time [10 msec]:
'Signal On' period (in 10 msec units) for the first
cadence on-off cycle. For be continuous tones, this parameter defines the
detection period. For burst tones, it defines the tone's duration.
•
First Signal Off Time [10 msec]:
'Signal Off' period (in 10 msec units) for the first
cadence on-off cycle (for cadence tones). For burst tones, this parameter defines
the off time required after the burst tone ends and the tone detection is reported.
For continuous tones, this parameter is ignored.
•
Second Signal On Time [10 msec]:
'Signal On' period (in 10 msec units) for the
second cadence on-off cycle. Can be omitted if there isn't a second cadence.
•
Second Signal Off Time [10 msec]:
'Signal Off' period (in 10 msec units) for the
second cadence on-off cycle. Can be omitted if there isn't a second cadence.
•
Third Signal On Time [10 msec]:
'Signal On' period (in 10 msec units) for the
third cadence ON-OFF cycle. Can be omitted if there isn't a third cadence.
Summary of Contents for Mediant 2000
Page 1: ...Document LTRT 68808 November 2008 User s Manual Version 5 6 ...
Page 2: ......
Page 18: ...SIP User s Manual 18 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 254: ...SIP User s Manual 254 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 334: ...SIP User s Manual 334 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 342: ...SIP User s Manual 342 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 408: ...SIP User s Manual 408 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 414: ...SIP User s Manual 414 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Page 418: ...User s Manual Version 5 6 www audiocodes com ...