Manual Weighing Controller A 810
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Page
55
d A C
3.1.12.4. Limit definition “LIM”
This selection is required to define
whether the output range (defined at
3.1.12.3 “NI”) should be related to
on: 0…100% fullscale
off: UNDER to OVERLOAD – Limits
(refer to “”LUNL” and “LOVL” at page 27)
default setting: on
3.1.12.5. Error case “Err”
This toggle decision defines whether
in case of OVERLOAD the output
is set to
on: output like at Zero weight
off: output like at MAX weight
default setting: off
3.1.12.6. constant analog
output “SPFix”
This selection defines whether the analog
signal is continiously output accordant to
weight or is fixed output accordant to
setpoints (SP1, SP2, CPS) to control
external electronics.
(3.1.12.6 at page 68)
on: fixed output accordant to setpoints
off: output proportional weight
default setting: off
3.1.12.7. Set to default “dEF”
Toggled decision to set all parameters
of the “DAC” sub menu to the default
values when ON.
TARE
n
d E F
ENT
o F F d E F
o
d E F
/NET
GROSS
0
TARE
TARE
TARE
n
L I M
ENT
o F F L I M
o
L I M
/NET
GROSS
0
TARE
0
/NET
GROSS
n
E r r
ENT
o F F E r r
o
E r r
/NET
GROSS
0
TARE
0
/NET
GROSS
TARE
n
S P F i x
ENT
o F F s p f i x
o
s p f i x
/NET
GROSS
0
TARE
0
/NET
GROSS
Summary of Contents for a810