Manual of Weighing Controller A 810
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Page
25
b A S I C
3.1.1.3. Range of zero setting
lower limit “LLZS”
The lower limit of zero setting range
can be adjusted between
0 … –20%
of full scale.
default setting: 1
3.1.1.4. Range of zero setting
upper limit “ULZS”
The upper limit of zero setting range
is adjustable between
0 … 20%
of FS
and indicates in which range the zero
setting function is operating.
default setting: 3
3.1.1.5. Zero tracking “ZT”
This toggle decision enables or disables
the zero tracking option.
default setting: off
3.1.1.6. Zero tracking
distance “dZT”
Set in terms of number of divisions
(tenth of division per second) in the
range of
0…100
.
Weight deviations within the
selected window that have been stable
for more than one second is tracked off.
Please note: zero tracking should be off
for most set point filling operations to
prevent tracking off any product trickle at
the start of the filling process.
default setting: 5 (0.5 divisions per second)
-1
+1
cursor
left
L L
Z
S
0
/NET
GROSS
ENT
0 1
/NET
GROSS
0
SHIFT
>
FUNC
value
incr. decr.
cursor
right
-1
+1
cursor
left
d Z T
0
/NET
GROSS
ENT
0 0 5
/NET
GROSS
0
SHIFT
>
FUNC
value
incr. decr.
cursor
right
TARE
TARE
TARE
-1
+1
cursor
left
U L Z S
0
/NET
GROSS
ENT
0 3
/NET
GROSS
0
SHIFT
>
FUNC
value
incr. decr.
cursor
right
TARE
Z T
0
TARE
/NET
GROSS
ENT
o F F Z T
o n Z T
/NET
GROSS
0
Summary of Contents for a810