Manual Weighing Controller A 810
Page
86
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
E_DAC0
Command No 4Eh
Parameters: voltage
This command is to set DA-converter to a voltage level.
Parameter 0 is equal to a voltage of 0V resp. a current of 0mA and the maximum of 4095
(FFFh) is equal to a voltage of 10V resp. a current of 20mA.
Example:
‘N2048’
output of 5V resp. 10mA at DA-converter
4.5.4. Behaviour in case of trouble
In normal conditions the terminal transmits data on request whereas in case of trouble an error message
resulting in the shut-down of the scale program is transmitted compulsorily at the time when it is read out
by the display. Acknowledge the error message either by pressing key 'Test' or by transmitting key code
'C' via PC interface.
Error data record:
* identifier
'F' for error
* number
ASCII string (max. 2 digits)
Example: 'F13'
Breakdown
of
positive supply voltage ADC 1