Manual of Weighing Controller A 810
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Page
45
s
E Q U
3.1.8.4. Auto free fall
compensation
“AFFC”
Toggled decision to set “Auto free fall
compensation” ON or OFF.
default setting: off
Refer to application note 6.9 at page 107.
3.1.8.5. Auto free fall
compensation
counter ”AFFC-CN”
Set in terms of numbers between 0…9
of completed weighing cycles to take
into account for compensation.
default setting: 4
3.1.8.6. CPS coefficient “CPS-CE”
Set in terms of numbers between 0…3
of weighting.
0: 0.25
1: 0.5
2: 0.75
3: 1
default setting: 0
3.1.8.7. Near zero
confirmation “NZC”
Toggled decision to ensure a “near zero”
condition during starting a cycle.
When no “near zero” condition is detected
“Err 104” is shown.
default setting: off
A F F C -
C N
0
/NET
GROSS
ENT
/NET
GROSS
0
FUNC
-1
+1
cursor
left
4
SHIFT
>
value
incr. decr.
cursor
right
A F F C
o f f A F F C
o n A F F C
/NET
GROSS
0
0
TARE
/NET
GROSS
ENT
N
Z C
o F F
N
Z C
o n
N
Z C
/NET
GROSS
0
0
TARE
/NET
GROSS
ENT
C P S
-
C E
0
/NET
GROSS
0
ENT
/NET
GROSS
0
-1
+1
value
incr. decr.
TARE
TARE
TARE
TARE
Summary of Contents for a810