7.3. Description of States of Error
When an error occurs, the terminal reads out an error message in place of weight. Apart from underload
and underload, every error message has to be acknowledged by pressing key 'Set to zero'. Depending on
the type of error, the terminal will either restart or continue its operation. Trace the cause of the error and
eliminate it whenever it occurs one more time. 7.3 shows all possible error messages as well as possible
sources of error.
Error
Message
Error
Cause
∪∪∪∪∪∪
underload (compound scale: possibly
followed by number of channel with
underload)
load carrier is lifted, load cell(s) defective,
faulty measuring cable
∩∩∩∩∩∩
overload (compound scale: possibly
followed by number of channel with over-
load)
excessive load, load cell(s) defective, faulty
measuring cable
Err 0
error RAM test
terminal defective
Err 1
error proof sum ROM section
terminal defective
Err 2
error proof sum Flash ROM
terminal defective
Err 3
write error Flash
terminal defective
Err 4
data error real-time clock
terminal defective
Err 5
no active Setup found
terminal defective
Err 6
more than one active Setups
terminal defective
Err 10 AD converter 1, time-out in calibration
cycle
terminal defective
Err 11 AD converter 1, time-out in conversion
cycle
terminal defective
Err 12
AD converter 1, overflow buffer of
measured data
terminal defective
Err 13 AD converter 1, positive load cell voltage
supply missing
interruption or short circuit of power supply
circuit
Err 14 AD converter 1, negative load cell voltage
supply missing
interruption or short circuit of power supply
circuit
Err 15 AD converter 1, input signal below input
signal range
defective load carrier, erroneous connection of
measuring cables, erroneous ADC setting
Err 16 AD converter 1, input signal in excess of
input signal range
defective load carrier, erroneous connection of
measuring cables, erroneous ADC setting
Err 20 AD converter 2, time-out in calibration
cycle
terminal defective
Err 21 AD converter 2, time-out in conversion
cycle
terminal defective
Err 22
AD converter 2, overflow buffer of
measured data
terminal defective
Err 23 AD converter 2, positive load cell voltage
supply missing
interruption or short circuit of power supply
circuit
Err 24 AD converter 2, negative load cell voltage
supply missing
interruption or short circuit of power supply
circuit
Err 25 AD converter 2, input signal below input
signal range
defective load carrier, erroneous connection of
measuring cables, erroneous ADC setting
Err 26 AD converter 2, input signal in excess of
input signal range
defective load carrier, erroneous connection of
measuring cables, erroneous ADC setting