Manual Weighing Controller A 810
Page
46
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
S E
Q U
3.1.8.8. Setpoint SP1
confirmation “SPC”
Toggled decision to ensure a weight
below SP1 during starting a cycle.
When weight is higher SP1
“Err 105” is shown.
default setting: off
3.1.8.9. Wait discharge gate
open “dISO-TI”
Set in terms of numbers between
50…9999ms.
During that time in sequence mode a
signal has to be on input D18 or D19
(with user function “230” p.109 associated)
otherwise a weighing cycle is aborted
with “Err109”.
default setting: 0
3.1.8.10. Discharging time
“dIS-TI”
Set in terms of numbers between
50…9999ms. After the “Complete Signal”
turns ON, the “Discharge” Signal turns ON
for that time.
default setting: 3000
3.1.8.11. Wait discharge gate
close “dISC-TI”
Set in terms of numbers between
50…9999ms.
default setting: 0
S P C
o F F S P C
o n S P C
/NET
GROSS
0
TARE
ENT
0
/NET
GROSS
TARE
d I S O -
T I
0
/NET
GROSS
5 0
ENT
/NET
GROSS
0
-1
+1
value
incr. decr.
TARE
d I S -
T I
0
/NET
GROSS
5 0
ENT
/NET
GROSS
0
-1
+1
value
incr. decr.
TARE
d I S C -
T I
0
/NET
GROSS
5 0
ENT
/NET
GROSS
0
-1
+1
value
incr. decr.
TARE
Summary of Contents for a810