3.1.6. Submenu “Control”
This submenu defines the settings whether the A810 is working in “Comparison Mode” and “Sequence
Mode” and certain in- and outputs.
3.1.6.1. Sequence mode
selection “SMS”
This toggled decision defines whether the
device is used in sequence mode or
in comparison mode.
off: comparison mode
on: sequence mode
default setting: off
3.1.6.2. Feeding / Discharging
control “Fd-Con”
This defines how the device is working
regarding Feeding / Discharging application.
It is only available in comparison mode.
0: feeding
1: discharge
2: external control
default setting: 0
3.1.6.3. Complete signal
output mode “CSO-
MD”
This selection defines when the
“complete” signal is active at pin B12.
The duration of “complete output signal”
depends on “complete output time”
3.1.7.8 “COTI” at page 43.
0: judging time is expired
1: after stable condition is set and judging
time is expired
2: after CPS is set, stable is set or judging
time is expired
default setting: 0