Manual of Weighing Controller A 810
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Page
41
C O
M P
3.1.7. Submenu comparison mode “COMP”
All settings in this submenu are for the basic behaviour in “Comparison Mode” and “Sequence Mode”.
3.1.7.1. Near-Zero-Compare “nZC”
This selection defines whether Gross or Net
will be used to carry out the
Near-Zero-Compare mode.
0: compare with gross weight
1: compare with net weight
2: comparison off
default setting: 0
3.1.7.2. Final-Over-Under-
Compare “FOU-CMP”
This selection is to define whether Gross
or Net is taken into account regarding
Final-Over-Under-Compare mode.
This setting is used for setpoints SP1, SP2
and SP3/CPS as well.
0: compare with gross weight
1: compare with net weight
2: comparison off
default setting: 0
3.1.7.3. Upper-Lower-Limit-
Compare “ULL-CMP”
This selection is to define whether Gross
or Net is taken into account regarding
Upper-Lower-Limit-Compare mode.
0: compare with gross weight
1: compare with net weight
2: comparison off
default setting: 0
TARE
F O U - C M P
0
0
/NET
GROSS
ENT
/NET
GROSS
0
-1
+1
value
incr. decr.
U L L - C M P
0
0
/NET
GROSS
ENT
/NET
GROSS
0
-1
+1
value
incr. decr.
TARE
TARE
n Z C
0
0
/NET
GROSS
ENT
/NET
GROSS
0
-1
+1
value
incr. decr.
ENT
Summary of Contents for a810