Manual Weighing Controller A 810
Page
72
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
2 3 1 4 5
d E L A c c
o F F A c c
o n A c c
3.2.4. Show accumulation total sum (3)
Funtion Call 196: According present selected code. Parameter “FOU-CMD” (3.1.7.2 at page 41) defines
wheter Net or Gross weight is accumulated. Scrolling is done when accumulation sum is greater than
999.999.999. Maximum total sum can be up to 4.294.967.295, where decimal point is irrelevant. At
highest resolution of 100.000 more than 42 thousend weighing cycles can be accumulated. If the
maximum total sum is exceeded, “Err 120” is generated.
FUNC
3
NEAR Z
return to weighing mode
3.2.5. Show accumulation count (4)
Funtion Call 194: According present selected code.
FUNC
4
SP1
return to weighing mode
3.2.6. Clear active accumulated sum (5)
Funtion Call 192: According present selected code, this function clears total sum and counter.
FUNC
5
SP2
TARE
TARE
/NET
GROSS
0
TARE
ENT
value scrolls when greater than 999 999 999
Summary of Contents for a810