Models GP100 / GP250

Electronic General Purpose Bench Scale

User Manual

Summary of Contents for GP100

Page 1: ...8271 Models GP100 GP250 Electronic General Purpose Bench Scale User Manual ...

Page 2: ...carton for future use 2 Place the scale on a flat level surface free from vibration 3 Remove the AC adapter and user manual from the packaging material INSTALLING THE BATTERY Use 9V ALKALINE BATTERY ONLY No other type provides a suitable power output To fit the battery remove the cover on the underside of the scale and place the battery firmly into the battery holder a Connect the terminals to the...

Page 3: ...B or Kilograms KG When powering the scale on the units of measure default LB or KG will be used depending on your country of origin The displayed weight being used can be identified by checking to make sure the bullet on the display is pointing to LB or KG See page 7 for detailed instructions on changing the default units of measure or deactivating the UNITS button TARE The tare feature is used wh...

Page 4: ...nt Note It is recommended to press the ZERO ON OFF key before placing an item on the scale This will help ensure accurate weight readings TARE KEY To use the tare feature 1 Place an empty container on the weighing platform 2 Press the TARE key The scale will display zero weight 3 When an item is placed on the container the scale only displays the weight of the item not the weight of the container ...

Page 5: ...isplayed weight HOLD KEY This key is used when you are unable to view the displayed weight because an item is larger than the weight platter and display Pressing this key will hold the stable weight in the display after the package has been removed To use the Weight Hold feature 1 Remove all items from the scale making sure the scale is at zero weight 2 Press the HOLD key A bullet will flash indic...

Page 6: ... UNITS key to scroll to the next selection A OFF Press TARE key to enter into the AUTO POWER OFF configuration menu 120 120 seconds Press the TARE key to accept this setting or the UNITS key to scroll between 240 240 seconds or OFF After selecting your desired setting and pressing the TARE key to accept A OFF Press the UNITS key twice to scroll to END Press the TARE key to exit the setting and ret...

Page 7: ...ructions Function Scale Response 1 Make sure the scale is turned off 2 Remove all weight from the scale 3 Press and hold the ZERO key and press the UNITS key three times CAL 4 Press the UNITS once to accept and enter into calibration mode 1000 4000 5 Press the TARE key once to zero the scale 0 6 Place XX see Table 1 weight on the scale See Table 2 7 Press TARE key once to accept the calibration we...

Page 8: ...BS only Press the TARE key enter into configuration menu KG Press TARE key ON Press the UNITS key once to scroll to OFF Press TARE key 0 1 Press the TARE key KG Press the UNITS key 5 times END Press the TARE key to exit the setting and return the scale to 0 0 weight TECHNICAL SUPPORT For technical support and more product details please contact us Via Phone 507 238 8702 or 1 800 637 0529 Via Fax 5...

Page 9: ... the scale before placing an item on the scale OR Ensure scale is placed in a stable level environment free from vibration OR Turn the scale Off then back on Lo is displayed Replace the battery Over is displayed The weight placed on the scale is over the scales capacity Remove the weight from the scale OR The weight placed on the scale plus the Tare weight is over the scales maximum capacity Remov...

Page 10: ...rror turn the scale off then on again OR Zero key is stuck Gently free ZERO button Unit will not stay on Auto Power Off is activated See page 5 for configuration Backlit display does not work Display is broken I lost my power supply and battery cover Contact the factory at 1 800 637 0529 for replacement parts Incorrect Hold Weight Scale was not able to stabilize and determine a hold weight repeat ...

Page 11: ...rror turn the scale off then on again OR Zero key is stuck Gently free ZERO button Unit will not stay on Auto Power Off is activated See page 5 for configuration Backlit display does not work Display is broken I lost my power supply and battery cover Contact the factory at 1 800 637 0529 for replacement parts Incorrect Hold Weight Scale was not able to stabilize and determine a hold weight repeat ...

Page 12: ...e the scale with care Dropping the scale may cause damage to the scale which will not allow the scale to weigh properly This type of damage is considered abuse and violates the product warranty 2 To avoid damage to the scale never drop heavy objects or exceed 400 lbs or 200 kg of weight on the scale 3 Clean the scale with a slightly damp cloth DO NOT immerse the scale in water or use chemical abra...

Page 13: ...ducts 1000 Armstrong Dr Fairmont Minnesota 56031 Toll Free 800 637 0529 Voice 507 238 8702 Fax 507 238 8271 Email sales salterbrecknell com www salterbrecknell com January 2004 Copyright 2001 2004 Salter Brecknell Weighing Products ...