154
FX023
10. Replace the O-ring on the IFP. Apply a thin layer of
molybdenum grease to the body before installing the
IFP into the body with the IFP relief contour facing
towards the top of the body.
FX022
FX021
11. Apply Loctite Primer #7649 to the body and set the
IFP depth.
FX1020
FX019
NOTE: When setting IFP depth, note the shock
absorber IFP shuttles 0.480” during installation.
A. The designed depth of the IFP must be decreased
by 0.480” on the this shock absorber when the IFP
depth is determined from the top of the body.
B. Example: 8.164”-0.480” = 7.684” installed IFP
depth.
NOTE: Handle the body carefully once the IFP is
set.
12. Replace the O-ring in the body cap. If the shock has
been rebuilt several times, the body cap assembly may
need to be replaced.
FX018
13. Apply green Loctite #638 two threads wide for 360°
two threads up from the start of threads. Ensure the
Loctite does not make contact with the O-ring. Secure
the body in Gas Shock Rod/Body Clamping Tool and
tighten the body cap to 75 ft-lb.
FX017