C.12 Option 17: Parallel BCD Output and Second RS-232 Port
135
C.12
Option 17: Parallel BCD Output and Second RS-232 Port
C.12.1
General Description
Option 17 for the Model 1088A/B clocks expand the capabilities of the instrument to include:
•
Either of the following:
a. Time-of-year output in Binary-Coded Decimal (BCD) format, with resolution down to
1 millisecond; or
b. Parallel Data output, with up to 48 bits that can be custom-configured at the factory
for specific applications;
•
A continuous 1 pulse-per-second (1 PPS) output, with the rising edge of a 10 millisecond-wide
pulse synchronous to the rising edge of 1 PPS/GPS;
•
A continuous 1,000 PPS (1 kPPS) square wave output, with rising edges synchronous to the
rising edge of 1 PPS/GPS;
•
Four pins of the output connector that can be configured with combinations* of the following:
a. Up to four digital signal outputs, the functions of which can be selected individually
from 18 choices.
b. Up to two analog signal outputs, the functions of which can be selected individually
from two choices.
c. An RS-232C serial communications port, which can use between two and four lines.
*Note:
Since these auxiliary functions must share four connector pins, certain limitations will
apply when selecting combinations:
•
Enabling any one (or more) of the digital signal outputs precludes four bits from the parallel
data output, if used;
•
Each analog signal output used precludes one of the digital signal outputs; if two analog signal
outputs are employed, only two digital signal outputs are possible. Also, each analog signal
output displaces one bit from the parallel data interface, if used;
•
A two- or four-wire RS-232C port configuration uses two or four of the data output lines, so
these lines become unavailable for digital and/or analog signal outputs, or for the assigned
data bits of the parallel output (if used).
Summary of Contents for 1088A
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii LIST OF FIGURES ...
Page 23: ...1 4 Attaching Rack Mount Ears to 1088A B Series Clocks 3 Figure 1 2 Attaching Rack Mount Ears ...
Page 24: ...4 Unpacking the Clock ...
Page 32: ...12 Front and Rear Panels ...
Page 38: ...18 Connecting Inlet Power Input and Output Signals ...
Page 46: ...26 GPS Antenna and Cable Information ...
Page 48: ...28 Setting Internal Jumpers Figure 5 1 Model 1088B Main Board ...
Page 76: ...56 The Setup Menus ...
Page 112: ...92 Serial Communication and Command Set ...
Page 127: ...B 4 Physical Dimensions 107 Figure B 1 Suggested Mounting of the AS0094500 Surge Arrester ...
Page 128: ...108 Using Surge Arresters ...
Page 145: ...C 5 Option 04 Parallel BCD Output 125 Figure C 4 Option 04 Output Jumper Settings ...
Page 146: ...126 Options List Figure C 5 Option 04 Board Layout and Jumper Locations ...
Page 166: ...146 Options List Figure C 12 Option 17 Board Layout and Jumper Locations ...
Page 187: ...C 16 Option 20A Four Fiber Optic Outputs 167 Figure C 22 Option 20A Jumper Locations ...
Page 194: ...174 Options List Figure C 24 Option 23 Internal Jumper Setup ...
Page 196: ...176 Options List Figure C 25 Option 27 Jumper Locations ...
Page 214: ...194 Options List Figure C 28 Option 29 Connector Signal Locations ...
Page 270: ...250 Options List ...