C.21 Option 32/33: NTP Server – Obsoleted by Opt34
199
c)
Open a telnet connection to port 9999 and set all required parameters.
telnet 192.168.0.232 9999
NOTE:
The temporary IP address is reverted after every power reset of the NTS. Be sure to enter
the configuration and store the parameters to make the changes permanent.
After making a connection to configure the NTP server (either through the Ethernet or RS-232
port), the screen should display the top four lines; to enter the Setup Mode, you must press Enter
on the terminal (pc).
*** NTS ***
MAC address 00204AAB5F03
Software version V5.8.13.RC2 (050126) CPK 580 M100
Press Enter to go into Setup Mode
*** basic parameters
Hardware:
Ethernet TPI
IP addr 192.168.0.232, no gateway set
*** Security
SNMP is
enabled
SNTP Community Name:
public
Telnet Setup is
enabled
TFTP Download is
enabled
Port 77FEh is
enabled
ECHO is
enabled
*** NTS parameters
Antenna Type:
GPS/Arbiter
SNTP Ref.Identifier:
‘‘gps2"
Encryption is disabled
Sending UDP datagram to Port 024C(hex) every 000 minutes
Send UDP datagram to:
Change Setup:
0 Basic configuration
1 NTS configuration
6 Security
7 Factory defaults
8 Exit without save
9 save and exit
Your choice ?
Serial
An ASCII terminal or PC with a terminal emulation can be connected to the option RS-232 port,
but JMP2 and JMP3 must be set to “C” (for Ethernet Port 1) or “D” (for Ethernet Port2), and
JMP4 set to “B”. The terminal (or PC) should be configured to 9600 Baud, 8 data-bits, 1- stop
bit, no parity. The power must be cycled to enter the configuration mode. The self-test begins
after power-up. About a half-second later the Error (red) LED starts blinking. Now send three
Summary of Contents for 1088A
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii LIST OF FIGURES ...
Page 23: ...1 4 Attaching Rack Mount Ears to 1088A B Series Clocks 3 Figure 1 2 Attaching Rack Mount Ears ...
Page 24: ...4 Unpacking the Clock ...
Page 32: ...12 Front and Rear Panels ...
Page 38: ...18 Connecting Inlet Power Input and Output Signals ...
Page 46: ...26 GPS Antenna and Cable Information ...
Page 48: ...28 Setting Internal Jumpers Figure 5 1 Model 1088B Main Board ...
Page 76: ...56 The Setup Menus ...
Page 112: ...92 Serial Communication and Command Set ...
Page 127: ...B 4 Physical Dimensions 107 Figure B 1 Suggested Mounting of the AS0094500 Surge Arrester ...
Page 128: ...108 Using Surge Arresters ...
Page 145: ...C 5 Option 04 Parallel BCD Output 125 Figure C 4 Option 04 Output Jumper Settings ...
Page 146: ...126 Options List Figure C 5 Option 04 Board Layout and Jumper Locations ...
Page 166: ...146 Options List Figure C 12 Option 17 Board Layout and Jumper Locations ...
Page 187: ...C 16 Option 20A Four Fiber Optic Outputs 167 Figure C 22 Option 20A Jumper Locations ...
Page 194: ...174 Options List Figure C 24 Option 23 Internal Jumper Setup ...
Page 196: ...176 Options List Figure C 25 Option 27 Jumper Locations ...
Page 214: ...194 Options List Figure C 28 Option 29 Connector Signal Locations ...
Page 270: ...250 Options List ...