© ANITA
MP03700EN_181101
49
Installation
1. Insert the new rotary hook into the
mounting hole
⑪
.
2. Install the needles
①
.
3. While referring to pages 34, adjust
so that the rotary hook tip
⑭
is
aligned with the center of the needle
①
when the needle bar is raised
from its lowest potation until
reference line
ⓑ
at the bottom of
the needle bar
⑫
is aligned with the
lower edge of the needle bar
supporter
⑬
tighten ten the three
screws
⑨
.
NOTE:
In order to prevent the torque from
becoming too high, tighten all three
screws
⑨
less than fully, and then
turn them all again to tighten them
fully.
www.garudan.cz