© ANITA
MP03700EN_181101
32
[GF-2207-147, GF-2207-447]
Needle bar lift amount
GF-2207-147
GF-2210-447
F
(L)
M
(L)
M
Stitch Length
2 mm
2 mm
3 mm
3 mm
Needle bar height (H)
2.4 mm
2.4 mm
2.4 mm
7. Remove the needle plate.
8. Remove the feed dog.
9. Set the stitch length to either 2 (appros 2mm) or 3 (appros 3mm)on the scale, depending on the
model and specifications of the machine(Refer to the table).
10. Turn the machine pulley to raise the needle bar
⑫
by Hmm from its lowest Position (refer to the
table below for the value for H).
11. The reference line
ⓑ
on the needle bar
⑫
will be aligned with the lower edge of the needle bar
supporter
⑬
. The rotary hook tip
⑮
must be aligned with the center of the needle at this time.
12. Tilt back the machine head, loosen the three screws
⑯
, and then align the rotary hook tip
⑯
with the center of the needle.
13. Tighten the screws
⑯
.
14. The distance from the upper edge of the needle hole to the rotary hook tip
⑮
must be 1-1.5mm
when the rotary hook tip
⑮
is aligned with the center of the needle.
15. Install the feed dog.
16. Install the needle plate.
www.garudan.cz