Adjust the rotary hook base
Make the following adjustment when
replacing the current gauge with one
wider, the feed dog cannot be installed if
this adjustment is not made.
Loosen screw
Ⓐ
,
Ⓑ
,
Ⓒ
and
shift the
rotary hook base right or left.
Installation
1. Attach the needle clamp.
2. Attach the needle.
3. Attach the feed dog.
[GF-2207-147, GF-2210-147]
1) Turn the machine pulley and check that
the needle goes into the middle of the
needle hole in the feed dog.
2) Loosen
②
and align the needles so that
the needles will fall in the centers of the
needle holes in the feed dog.
www.garudan.cz