© ANITA
MP03700EN_181101
29
Operating range of thread take-up spring
The standard operating range for thread
take-up spring L
①
and thread take-up
spring R
②
is 5-10mm for both springs.
1. Loosen the left and right screws
③
and
then turn the left and right thread take-up
spring stoppers
④
to adjust the operating
range.
2. Tighten the screws
③
.
Thread take-up spring operation timing
The standard operation take-up spring L
①
and thread take-up spring R
②
is the middle position
within the operating range of the thread take-up spring guide
⑩
,
1. Loosen the screw
⑪
2. Loosen the knob
⑥
, and then turn the left and right thread take-up spring guided
⑩
to adjust
the tension.
3. Tighten the screw
⑪
,and then tighten the knob
⑥
.
www.garudan.cz