10. REPLACING GAUGE PARTS (CHANGING THE NEEDLE WIDTH)
How to change gauges
1. Turn the machine pulley to move the needle bar to its
highest position.
2. Remove the needle
①
.
3. Remove the slide plate
②
.
4. Remove the needle clamp
③
.
5. Raise the presser foot by using the presser foot lifter
④
.
6. Remove the presser foot
⑤
.
7. Remove the needle plate
⑥
.
8. Remove the feet dog
⑦
.
9. Tilt back the machine head.
www.garudan.cz