Displaying Stream Content
172
VG-Series Modero Touch Panels
Step 2: Configuring the MAX-CSE for communication
1.
Complete the procedures outlined within the
Configuring the MAX Communication Parameters
section of the MAX-CSE Instruction Manual to establish an active connection to the source
MAX-CSE.
2.
Confirm the MAX-CSE is properly configured to use the newly established Static IP Address by
launching your browser and entering the MAX’s new Static IP Address into the browser’s
Address
field.
3.
Press the
Enter
key on your keyboard to initiate the communication process and launch the initial
on-screen Enter Network Password security dialog.
4.
Enter the words
administrator
and
password
(if using the default login profile)
into the
corresponding
User Name/Password
fields. This is the factory default security login information.
5.
Click
OK
to enter the information and proceed to the Administration page which provides both a
descriptive overview of the program stream and lists the currently used firmware.
6.
Determine the data throughput available on the network being used by the source encoder. This
information determines which Encoder Profile and Transport Protocol will be used to encode the
outgoing media stream.
7.
Access Stream Profiles page (FIG. 129) by clicking the
Stream Profiles
link from within the
Navigation frame. This page allows a user to both configure the properties of the outgoing media
stream and setup the properties associated with communicating the stream to an external IP-enabled
device capable of receiving and processing the data.
8.
From the
Profile
field, click on the drop-down arrow and from the available list, choose the desired
encoder setting which conforms to the available data throughput on your network. Although the
default selection is
Home Theater (Max)
, the user can choose from up to 6 pre-created entries and
one
Custom
entry which makes every field user-definable.
For the purpose of these procedures, we’ve been informed that our network can handle the full
6 Mbps data throughput, so we’ll select
Home Theater (Max)
.
FIG. 129
Stream Profiles page
Encoding Presets (including Custom)
Video Encoding Parameters
Stream Destination
Communication/Connection
Audio Encoding Parameters
Parameters
(use even port values)
Summary of Contents for Modero NXT-1500VG
Page 4: ......
Page 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Page 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Page 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Page 250: ...Appendix 240 VG Series Modero Touch Panels...
Page 251: ...Appendix 241 7 Modero Widescreen Touch Panels...