Touch Panel Accessories
30
VG-Series Modero Touch Panels
The following table provides the wiring information for each of the four (4) available connectors on each
side of the NXA-MTC/RGB Tabletop Cable.
Installing CAT5 Suppression Ferrites
Before connecting the RJ-45 cables to the Modero Touch Panel, install the necessary number of CAT5
Suppression Ferrites (FIG. 10) to the RJ-45 Audio/Video cable. These ferrites come as part of the
Installation Kits mentioned in the previous Specification table (page 28).
No tools are required for this installation.
1.
The CAT5 Suppression Ferrite is housed within a plastic enclosure (shown in FIG. 10) with a latch
release on one side. Pull to release the latch and open the enclosure.
2.
Grasp the Black RJ-45 Audio/Video cable being connected to the panel. This end of the cable is
longer than the opposing end which connects to the breakout box (6 inches vs 3 inches).
Refer to FIG. 11 for more detailed information.
3.
Insert the panel-end of the Black RJ-45 Audio/Video cable into the groove along the inside of the
enclosure.
4.
Snap the enclosure shut with the cable inside, and you’re done.
Wire Table
Wire
Connector 1 Connector 2
Connector 3 Connector 4
1
White/Orange
White/Orange
Red White/Orange
2
Orange/White
Orange/White
Black
Orange/White
3
White/Green
White/Green
-
White/Green
4
Blue/White
Blue/White
-
Blue/White
5
White/Blue
White/Blue
-
White/Blue
6
Green/White
Green/White
-
Green/White
7
White/Brown
White/Brown
-
White/Brown
8
Brown/White
Brown/White
-
Brown/White
FIG. 10
Installing the CAT5 Suppression Ferrites
Release the latch to
open the plastic
enclosure.
Insert the CAT5
cable and close
the enclosure.
Push down on the
enclosure until it
snaps closed.
All 1200V-Series, VG-Series, and Table Top CV10 panels require the installation of
an appropriate number of CAT5 Suppression Ferrites when they use an RJ-45 cable
to feed an A/V signal from the breakout box.
The CAT5 Suppression Ferrites MUST be installed onto the cable connected to the
Modero’s Audio/Video RJ-45 connector (just behind the connector).
Summary of Contents for Modero NXT-1500VG
Page 4: ......
Page 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Page 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Page 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Page 250: ...Appendix 240 VG Series Modero Touch Panels...
Page 251: ...Appendix 241 7 Modero Widescreen Touch Panels...