Firmware Pages and Descriptions
154
VG-Series Modero Touch Panels
Protected Setup Page
The Protected Setup page (FIG. 117) centers around the properties used by the panel to properly
communicate with the NetLinx Master. Enter the factory default password (
1988)
into the password
keypad to access this page.
The elements of the Protected Setup page are described in the table below:
FIG. 117
Protected Setup page-showing default values
Protected Setup Page Elements
Back:
Saves the changes and returns you to the previously active touch panel page.
Connection Status icon:
This visual display of the connection status allows the user to have a current
visual update of the panel’s connection status regardless of what page is
currently active.
• A Lock only appears on the icon if the panel has established a connection
with a currently secured target Master (
requiring a username and password
).
Device Number:
Opens a keypad that is used to set and display the current device number.
Options:
Allows you to select various touch panel features:
• The
Function Show
button enables the display of the channel port and
channel code in the top left corner of the button, the level port and level code
in the bottom left corner, and the address port and address code in the
bottom right corner (see FIG. 119 for an example of the function locations).
• Use the
Page Tracking
button to toggle page tracking. When enabled, the
touch panel sends page data back to the NetLinx Master, or vice versa
depending on the touch panel settings.
• Use the
Telnet
button to enable or disable the telnet server on the panel. This
feature focuses on direct telnet communication to the panel.
• Use the
Front Button Setup Access
button to activate the grey Front Setup
Access button (located below the LCD) to access the firmware pages.
- Default condition is On.
- Press and hold this grey button for
3 seconds
to access the Setup page.
- Press and hold this grey button for
6 seconds
to access the Calibration
page.
Reboot Panel:
Pressing this button causes the panel to restart after saving any changes.
Provides access to the panel firmware
pages by enabling the grey front
- Setup page (after a
3 second
press/hold)
- Calibration page (after a
6 second
setup access button:
press/hold)
Summary of Contents for Modero NXT-1500VG
Page 4: ......
Page 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Page 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Page 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Page 250: ...Appendix 240 VG Series Modero Touch Panels...
Page 251: ...Appendix 241 7 Modero Widescreen Touch Panels...