Firmware Pages and Descriptions
152
VG-Series Modero Touch Panels
Battery Base Page Elements (Cont.)
Very Low Battery Warning:
The
Very Low Battery Warning
UP/DN buttons alter the time value
(in minutes) available on the battery (for use) before the panel displays a very
low battery warning. This indicates a near-term panel shutdown.
Range = 3 - 15, default = 5 min.
- This value can never exceed the Low Battery Warning value.
•
When the NXT-BP batteries (installed within the NXA-BASE/B battery
base) reach a point where they need to be recalibrated.
- A recalibration pop-up screen appears to ask whether or not you choose
to recalibrate the batteries at this time.
Battery Status fields:
This section provides the ability to monitor the current battery charge levels and
charge qualities:
• The
Combined Charge Status
bargraph indicates the combined power
charge available from both internal battery connection slots
(bargraph range = 0 - 100).
• The
Battery One Charge Status
bargraph indicates the power charge
available on the Slot 1 internal battery connection (bargraph range = 0 - 100).
• The
Battery One Quality
bargraph indicates the physical capacity (quality) of
the battery. Quality is the percentage of actual capacity vs. its rated capacity.
For optimal performance, a battery should be replaced when the quality
rating drops below 80%.
• The
Battery Two Charge Status
bargraph indicates the power charge
available on the Slot 2 internal battery connection (range = 0 - 100).
• The
Battery Two Quality
bargraph indicates the physical capacity (quality) of
the battery. Quality is the percentage of actual capacity vs. its rated capacity.
• The
Base Version
field indicates the firmware version being used by the
NXA-BASE/B Battery Base connected to the NXT Modero panel.
• The
Battery Level Port
field indicates the port being used to report the
combined charge status level back to the NetLinx Master on (set in TPD4).
• The
Battery Level
field indicates the level being used to report the combined
charge status level back to the NetLinx Master on (set in TPD4).
Battery Power Brightness
Limit:
The DISABLE/DISABLED button acts as a power save feature with two
available choices:
•
Disable
- activates the brightness limit set on the Modero panel and is used
to conserve battery power. Activating this feature causes the panel to
function at 80% of full brightness and overrides the Panel Brightness value
set on the Setup page.
This extends the battery usage time.
•
Disabled
- (
illuminated when selected
) deactivates this power save feature
and makes the panel use the specified Panel Brightness level set on the
Setup page.
The term "quality" (in the context of a battery), refers to the current capacity relative to
the batteries’ rated capacity. For example, after constant use, a battery may be
operating at 75% of its rated capacity even though it might be fully charged. In this
case, the battery could be incorrectly reporting its’ information back to the battery
base and then consequently relating this information back to the Battery Base page.
A battery can be recalibrated using an optional NXT-CHG (battery charger).
Summary of Contents for Modero NXT-1500VG
Page 4: ......
Page 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Page 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Page 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Page 250: ...Appendix 240 VG Series Modero Touch Panels...
Page 251: ...Appendix 241 7 Modero Widescreen Touch Panels...