Upgrading Modero Firmware
122
VG-Series Modero Touch Panels
5.
Press the
Back
button on the touch panel to return to the Protected Setup page.
6.
Press the on-screen
Reboot
button to both save any changes and
restart the panel.
Remember that
the panel’s connection type must be set to
USB
prior to rebooting the panel and prior to inserting
the USB connector.
7.
ONLY AFTER
the unit displays the first panel page,
THEN
insert the mini-USB connector into
the Program Port on the panel. It may take a minute for the panel to detect the new connection and
send a signal to the PC (
indicated by a green System Connection icon
).
If a few minutes have gone by and the System Connection icon still does not turn green,
complete the procedures in the following section to setup the Virtual Master and refresh the
System from the Online Tree. This action sends out a request to the panel to respond and
completes the communication (
turning the System Connection icon green
).
8.
Navigate back to the System Settings page.
Step 2: Prepare NetLinx Studio for communication via the USB port
1.
Launch NetLinx Studio 2.x (default location is
Start
>
Programs
>
AMX Control Disc
>
NetLinx
Studio 2
>
NetLinx Studio 2
).
2.
Select
Settings
>
Master Communication Settings
, from the Main menu to open the Master
Communication Settings dialog (FIG. 93).
3.
Click the
Communications Settings
button to open the
Communications Settings
dialog.
4.
Click on the
NetLinx Master
radio button (
from the Platform Selection section
) to indicate that you
are working as a NetLinx Master.
5.
Click on the
Virtual Master
radio box (
from the Transport Connection Option section
) to indicate
you are wanting to configure the PC to communicate directly with a panel. Everything else such as
the Authentication is greyed-out because you are not going through the Master’s UI.
6.
Click the
Edit Settings
button (
on the Communications Settings dialog
) to open the
Virtual NetLinx
Master Settings
dialog (FIG. 93).
ALL
fields are then greyed-out and read-only, but still display any previous network
information.
FIG. 93
Assigning Communication Settings for a Virtual Master
(not needed as this is a direct
USB connection)
IP Address of computer
Summary of Contents for Modero NXT-1500VG
Page 4: ......
Page 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Page 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Page 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Page 250: ...Appendix 240 VG Series Modero Touch Panels...
Page 251: ...Appendix 241 7 Modero Widescreen Touch Panels...