Configuring Communication
110
VG-Series Modero Touch Panels
IP Settings section - Configuring a Static IP Address over Ethernet
1.
Select
Protected Setup
>
System Settings
(located on the lower-left) to open the System Settings
page.
2.
Locate the IP Settings section of this page.
3.
Toggle the
DHCP/Static
field (
from the IP Settings section
) until the choice cycles to
Static
.
4.
Press the
IP Address
field to open a Keyboard and enter the Static IP Address (
provided by your
System Administrator
).
5.
Press
Done
after you are finished entering the IP information.
6.
Repeat the same process for the
Subnet Mask
and
Gateway
fields.
7.
Press the optional
Host Name
field to open the Keyboard and enter the Host Name information.
8.
Press
Done
after you are finished assigning the alpha-numeric string of the host name.
9.
Press the
Primary DNS
field to open a Keyboard, enter the Primary DNS Address (provided by your
System Administrator) and press
Done
when compete. Repeat this process for the
Secondary DNS
field.
10.
Press the
Domain
field to open a Keyboard, enter the resolvable domain Address (
this is provided by
your System Administrator and equates to a unique Internet name for the panel
), and press
Done
when complete.
11.
Navigate to the Master Connection section of this page to begin configuring the communication
parameters for the target Master.
Step 2: Choosing a Master Connection Mode Setting
There are three Ethernet MODE settings used in the Master Connection section of the System Settings
page.
URL is the most common method.
Master Connection MODE
options:
Check with your System Administrator for a pre-reserved Static IP Address assigned
to the panel. This address must be obtained before Static assignment of the panel
continues.
•
URL
(
Uniform Resource Locator
) is the address that defines the route to a file on the Web or
any other Internet facility.
In this system, the panel acts as a "Client" and the Master acts as a Server (in that Clients attach
to it).
•
LISTEN
sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from
its URL list). In this system, the panel acts as a "Server" (in that Clients attach to it) and the Master
acts as a "Client".
•
AUTO
is used to instruct the Modero to search for a Master that uses the same System Number
(assigned within the Master Connection section) and resides on the same Subnet as itself. In this
case, the Master has its UDP feature enabled.
This
UDP
(
User Datagram Protocol
) is a protocol within the TCP/IP protocol suite that is used in
place of TCP when a reliable delivery is not required.
This UDP enabling is done through a Telnet session on the Master. Refer to the particular NetLinx
Master manual for more detailed information.
Summary of Contents for Modero NXT-1500VG
Page 4: ......
Page 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Page 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Page 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Page 250: ...Appendix 240 VG Series Modero Touch Panels...
Page 251: ...Appendix 241 7 Modero Widescreen Touch Panels...