Chapter
11
95
ML-73
□□
EL
11.1 External Input and Output (EXT. I/O)
■
When counter stop is used (increment of 1)
*11 Do not change the counter input while marking-in-progress output is ON.
*12 A counter stop input is confirmed at the rising edge of marking start input.
*13 The counter value is increased or decreased during marking.
If multiple counters are used under the same conditions for a single layout and if
marking is stopped halfway, the counter values may not be the same.
Start of
Marking
n
n+1
n+2
n-1
Marking
Stops
*11
*12
Marking
Stops
Counter stop
input
Counter value
Marking start
input
Marking
in progress
output
Marking ready
output
*13
*13
Summary of Contents for ML-73 EL Series
Page 1: ...Z11OM1209102 02 Fiber Laser Marker ML 73 EL OPERATION MANUAL Original instructions...
Page 4: ......
Page 133: ...Appendix...