Chapter
9
57
ML-73
□□
EL
9.5 Commands
The commands are listed below.
The first three characters of a command segment signify specific command itself.
9.5 Commands
Command
Function details
Read
Write
Parameter
Setting increment/
details
CUR
CUW
Laser beam
Current
0.1A
LOR
LOW
Current offset
1%
SPR
SPW
Marking speed
0.01 mm/s
PUR
PUW
Frequency
0.1 kHz
RTR
RTW
X and Y axes
Axial rotation angle
0.000001
°
XOR
XOW
X-axis offset
1
µm
YOR
YOW
Y-axis offset
1
µm
XYR
XYW
X-axis offset
Y-axis offset
Axial rotation angle
1
µm
1
µm
0.000001
°
LMR
LMW
Laser control
Laser start
0: OFF
1: ON
MSR
MSW
Marking start
0: End
1: Marking in progress
GLR
GLW
Guide beam
0: OFF
1: ON
LNR
LNW
Layout number
selection
Layout number
RLR
RLW
Toggle local/external
control
0: Local (internal)
1: Remote (external)
SRR
SRW
Marking data
Serial
Serial number
VDR
VDW
Variable data
Variable number
VCW
Variable data
continuous change
Variable number
MRR
MRW
Marking data
Layout number
DMR
DMW
Number of cells of
DataMatrix, Cell part
setting
“Number of cells”
number, Part number
ARD
Matrix skip
Matrix number
LNS
Layout selection
(Filename designation)
Filename
MRS
Layout binary
registration
GNS
Part no. searching
Filename
GRS
Part binary registration
Summary of Contents for ML-73 EL Series