Chapter
9
70
ML-73
□□
EL
Chapter
9
Serial Interface Specifications
(30) ACR (Elapsed time for consumables)
Obtain the total hours the LD has been used.
■
Read (ACR)
(31) BAR/BAW (Transmission conditions)
Obtain (read) and set (write) communication conditions.
■
Read (BAR)
■
Write (BAW t0, t1, t2, t3, t4)
t0
Auto transmission regarding
marking readiness
0: Auto transmission
OFF
1: Auto transmission
ON
t1
Auto transmission regarding when
marking is finished
t2
Auto transmission of safety shutter
information
t3
Auto transmission of errors
* When 1 (auto transmission ON) is selected, S0 to 3 are sent each time the status changes.
* Note that enabling the marker initializes the settings, disabling auto transmission of all items.
Example
If the LD has been used for 1 hour
Computer ->
Marker
: ACR
Marker ->
Computer
: 3600 (Unit: 1 second)
Computer ->
Marker
: BAR
Marker ->
Computer
: s0, s1, s2, s3, s4
s0
Baud Rate
0: 4800, 1: 9600, 2: 19200, 3: 38400, 4: 57600,
5: 115200 bps
s1
Stop bit
0: 1 bit, 1: 2 bits
s2
Parity
0: No, 2: even, 3: odd
s3
Checksum
0: OFF, 1: ON
s4
Delimiter ETX
0: OFF, 1: ON
Example
If the conditions are 9600 bps, Stop bit 1 bit even parity, no checksum, and no delimiter ETX (initial
settings)
Computer ->
Marker
: BAW 1, 0, 2, 0, 0
Except for checksum, these conditions take effect when the marker is restarted.
Example
Summary of Contents for ML-73 EL Series
Page 1: ...Z11OM1209102 02 Fiber Laser Marker ML 73 EL OPERATION MANUAL Original instructions...
Page 4: ......
Page 133: ...Appendix...