Appendix
A
132
ML-73
□□
EL
Appendix
A
Troubleshooting
If no laser beam is projected, follow these steps as a corrective action.
A.3 If No Laser Beam Is Projected
No laser beam is emitted.
The required marking parameters and data
are assumed to be set in the controller.
*
To correct the problem, follow the
instructions given on the RAS screen.
Release the Emergency Stop switch,
and then input the error reset.
Short pins 4 and 5 of the remote
interlock connector, and then input
the error reset.
NO
YES
NO
NO
Does the computer
indicate an error?
Was the Emergency Stop
switch pressed?
Contact us.
Is the remote
interlock enabled?
(Applies only if
remote interlock
signals are used.)