![Allen Organ Company L-124 BRAVURA SERIES User Manual Download Page 48](http://html1.mh-extra.com/html/allen-organ-company/l-124-bravura-series/l-124-bravura-series_user-manual_2899400048.webp)
46
6. Modifying the Crescendo and Tuttis
The original factory settings include a second set of Tuttis and a second set of Crescendo
settings that can be altered to suit an organist’s needs.
Advance to the ‘CRESC/TUTTI B’ window function
(see section A-2)
. There are two
modes available in this window function, "SET" and "SHOW".
SET
Mode: Set mode allows the organist to create or edit a Crescendo B sequence.
SHOW
Mode: Show mode allows the organist to view the Crescendo B sequence using
the
ROTARY DIAL
on the GeniSys™ Controller or by using the Crescendo Shoe.
To toggle between modes press the
CURSOR
button on the GeniSys™ Controller until
the cursor is positioned on the mode name
(Set or Show)
. Turn the
ROTARY DIAL
to
change modes. The display will indicate which mode is activated.
To view the stops/drawknobs registered on the second (B) TUTTI I or TUTTI II, press
either TUTTI. This will cause all associated stops/drawknobs programmed on the
selected TUTTI to turn on.
Setting a Crescendo B Sequence:
The Crescendo includes 22 positions evenly dispersed along the Crescendo shoe’s range
of travel. To set a Crescendo B sequence, advance to the ‘CRESC/TUTTI B’ window
function
(see Section A-2).
Press the
CURSOR
button until the cursor is positioned on
the word “step” on line two. Turn the
ROTARY DIAL
to change the step positions.
The word "step xx" indicates that you are now editing or viewing
(dependent if SET or
SHOW mode is active)
the Crescendo B sequence. The "step xx" indicator will display
either "step --" to indicate position 0
(Crescendo shoe off)
or any step between 1 and 22.
Any stops/controls associated with a particular Crescendo step will indicate their status
when using the Crescendo Shoe only
. While in 'SET' mode, turning the
ROTARY
DIAL
will not cause the stops/controls to indicate their status.
To ‘SET’ a Crescendo B sequence, first make sure that
SET
mode is selected. Then,
press the
CURSOR
button to re-position the cursor and turn the
ROTARY DIAL
to
select step 1. Adjust the stops to a suitable registration for step 1.
(Note: You can play
the organ at any time to hear the selected registration)
Press
and hold the
SET
piston, then while holding
SET
press the
MEMORY
button in the GeniSys™ Controller. "DONE!!" will
briefly flash on the first line of the display to indicate the step
has been programmed.
CRESC/TUTTI B
SET step --
CRESC/TUTTI B
SHOW step --
CRESC/TUTTI B
SET
s
tep --